Increased Hydraulic Conductance of Dentine
patent tubules at dentine surface
- removing smear layer increases response to hydrodynamic stimuli in cats
- difficult to explain increased sensitivity to cold
- occluding tubules reverses hypersensitivity in man
maybe tubule contents changed
increases response of hydrodynamic receptors to a stimulus
allows oral toxins access to pulp
- increased pulpal tissue fluid pressure will tend to oppose this effect